Capabilities

Secure facilities, engineered from the ground up.

Every LPD project is planned around the compliance, security, and operational requirements of its tenant, at whatever classification level the program requires, not retrofitted to meet them after the fact.

Asset Types

Purpose-built space across the secure facility spectrum.

SCIF-Capable Buildings

Sensitive Compartmented Information Facilities built to ICD/ICS 705 standards, one of several classification levels we build to (see Security Levels below).

Secure Laboratories

Classified and unclassified research, engineering, and prototyping space for defense innovation and energy security programs.

Classified & Unclassified Office

Administrative and collaborative office space integrated alongside secure program areas within a single, purpose-built campus.

Flex & Prototyping Space

Adaptable engineering and light industrial space designed to accommodate evolving program and equipment requirements over the lease term.

SCIF-as-a-Service

Flexible, managed SCIF access for tenants that need secure space on a shorter-term or shared basis, an initiative under active development.

Critical Infrastructure

Power, fiber, and physical infrastructure sized and secured to support mission-critical uptime and evolving tenant demand.

Security Levels

Engineered to the classification your contract specifies, nothing more, nothing less.

Security requirements vary widely by program and agency. We build to the level your contract actually calls for, and partner with established, specialized security and compliance firms to execute the technical work at each tier.

Top Secret / SCI

SCIF · ICD/ICS 705

Sensitive Compartmented Information Facilities built to Intelligence Community Directive/Standard 705, covering construction hardening, TEMPEST considerations, and access control.

Secret & Below

Secure & Closed Areas · NISPOM

Closed areas and secure storage built to National Industrial Security Program Operating Manual requirements for classified information and material.

Controlled Unclassified

CUI-Compliant Space · NIST 800-171 / CMMC

Facilities built to support Controlled Unclassified Information handling requirements for defense contractors pursuing CMMC compliance.

Mixed-Use

Secure Labs & Blended Facilities

Classified and unclassified space combined within a single building, segmented to the appropriate level for each function and tenant group.

We don’t do this alone. For SCIF construction, TEMPEST mitigation, access control systems, and accreditation support, we partner with established, specialized security firms for design, construction and operations.

Site Selection

Sites are chosen for the mission, first.

Every site under consideration is evaluated against a consistent set of criteria before it enters the pipeline.

  • Demonstrated tenant demand from federal agencies, DoD, or cleared defense and intelligence contractors
  • Proximity to government installations: military bases, DoD facilities, national laboratories, and intelligence sites
  • Appropriate zoning and infrastructure for secure facility development, including power, fiber, and access control
  • Favorable political and economic development environment
  • Sufficient acreage and site geometry to meet secure facility setback and security requirements at the required classification level
  • Competitive land basis supporting target project returns
How We Deliver

From idea to tenancy, every step in between.

Once a contract is signed, the clock starts. These five stages take a project from an idea to an occupied, accredited facility.

  1. Site Selection & Control

    Sites are sourced and evaluated against LPD’s standard criteria, with priority given where tenant interest can be identified early.

  2. Design & Entitlement

    Architecture, civil, structural, and MEP design proceed alongside SCIF/ICD-705 compliance consulting and local entitlement processes.

  3. Horizontal & Vertical Construction

    Site infrastructure and core-and-shell construction are sequenced to support the security and hardening requirements of the finished facility.

  4. Tenant Improvements & Accreditation

    Security hardening appropriate to the required classification, from CUI controls to full SCIF construction, is built out alongside tenant-specific systems to support accreditation before occupancy.

  5. Asset Management

    LPD manages completed assets for long-term performance, tenant relations, and reinvestment over the lease term.

Have a tenant requirement or a site to discuss?

We work with agencies, prime contractors, and landowners to match secure facility demand with the right site.

Contact LPD